PRODUCT FEATURES
Torque range : 0.4 ~ 4.0 N.cm
It can be adjusted from 0.4 Ncm to maximum 4.0 Ncm and can be set in 0.1Ncm units.
RPM range : 200 ~ 1,200rpm
The rotation speed can be set from 200 rpm to 1,200 rpm.
It is 50rpm unit up to 1,000rpm and 100rpm unit above 1000rpm.
5 Operation Modes
Forward, Reverse, Auto Reverse Stop, Auto Reverse Run, Reciprocationg
8 Memory Programs
Selecting each number brings up the stored torque, rotation speed, and rotation mode
settings. You can save new settings in memory.
Continuous use
Available for 3 hours and 30 minutes with 1 hour and 30 minutes of full charge.
(※ Based on continuous no-load operation )
Root canal measurement function
High performance root canal length measurement function for safe and accurate
procedure Determination of length and procedure for treatment with a single device
without a separate measuring device Simplify proactive work by monitoring file
insertions during the procedure Clinical confirmation of root canal length
measurement accuracy.
(joint research with Seoul National University Dental Hospital)
Forward Mode

The motor rotates in forward direction and stops when the set torque value is reached.
Reverse Mode

The motor rotates in reverse direction, it does not stop even when the set torque value is reached.
Reciprocating mode

The motor reciprocates in the forward and reverse directions.
Rotate in the normal forward 150˚ / reverse 30˚the rotation value changes flexibly according to the load value.
Auto Reverse Stop mode

Set while the motor rotates in the forward direction reverse when the torque value is reached rotate
If the load is lower than the set torque value the motor stops.
Auto Reverse Run mode

Set while the motor rotates in the forward direction Reverse when the torque value is reached rotate
If the load is lower than the set torque value the motor will rotate in the forward direction again.
4.3inch graphic LCD display

4.3 inch full color LCD display Increased aesthetics.
Handpiece Holder

No need for a separate handpiece holder body unit type.
Soft touch type button

Intuitive interface with light touch Soft touch button method
Portable type controller (Wireless)

When moving or working the device with the charging type product
Easy to use, 5 hours with 2 and a half hours It can be
used continuousl.(at 10,000 rpm drive).





Footswitch that can be operated by stepping on any position
Upgraded from one-way drive switch 360 ° One-touch footswitch that can be driven anywhere.

PRODUCT FEATURES
Torque range : 0.4 ~ 4.0 N.cm
It can be adjusted from 0.4 Ncm to maximum 4.0 Ncm and can be set in 0.1Ncm units.
RPM range : 200 ~ 1,200rpm
The rotation speed can be set from 200 rpm to 1,200 rpm.
It is 50rpm unit up to 1,000rpm and 100rpm unit above 1000rpm
5 Operation Modes
Forward, Reverse, Auto Reverse Stop, Auto Reverse Run, Reciprocationg
8 Memory Programs
Selecting each number brings up the stored torque, rotation speed, and rotation mode settings.
You can save new settings in memory.
Continuous use
Available for 3 hours and 30 minutes with 1 hour and 30 minutes of full charge
(※ Based on continuous no-load operation )
Root canal measurement function
High performance root canal length measurement function for safe and accurate procedure Determination of length and procedure for treatment with a single device without a separate measuring device Simplify proactive work by monitoring file insertions during the procedure Clinical confirmation of root canal length measurement accuracy (joint research with Seoul National University Dental Hospital)
Forward Mode
The motor rotates in forward direction and stops when the set torque value is reached.
Reverse Mode
The motor rotates in reverse direction, it does not stop even when the set torque value is reached.
Reciprocating mode
The motor reciprocates in the forward and reverse directions. Rotate in the normal forward 150˚ / reverse 30˚the rotation value changes flexibly according to the load value.
Auto Reverse Stop mode
Set while the motor rotates in the forward direction reverse when the torque value is reached rotate If the load is lower than the set torque value the motor stops.
Auto Reverse Run mode
Set while the motor rotates in the forward direction Reverse when the torque value is reached rotate If the load is lower than the set torque value the motor will rotate in the forward direction again.
4.3inch graphic
LCD display


4.3 inch full color LCD display Increased aesthetics
Handpiece Holder

No need for a separate handpiece holder body unit type
Soft touch type
button


Intuitive interface with
light touch Soft touch
button method
Portable type controller

When moving or working the device with the charging type product Easy to use, 5 hours with 2 and a half hours It can be used continuous (at 10,000 rpm drive).
Footswitch that can be operated by stepping on any position
Upgraded from one-way drive switch 360 ° One-touch footswitch that can be driven anywhere